Hanyoung Programmable Temperature Controller TD500
ข้อมูลสินค้า
-
รหัสสินค้า
TD1
-
แก้ไขล่าสุดเมื่อ
01/12/2016 12:51
ดาวน์โหลดไฟล์ PDF
-
รายละเอียดสินค้า
Suffix code
Model Code Information TD500 - Programmable Temperature controller Types 1 Communication (RS485 / 422 Communication, USB) 2 Communication (RS232 Communication, USB) N None (only when need the I/O (input/ouput board)) Input-Output board 1 Contact input (DI) 8 contacts
Contact output (DO) 8 contacts
Transistor output (DO) 8 contactsN Non (Only necessary standard body) Language Korean/English (standard type) No code indication 2 English/Chinese (Simplified Chinese Character)
[Monitor specification] Screen rating Color STN LCD 144.78 mm (5.7") Number of pixels 320 X RGB X 240 Back light life expectancy CCFL(approx. 20,000 hrs)
Touch type Resistive type ( 4 wires)
Language Korean/English or English/Chinese (Simplified Chinese character) Displaying channel 2 channels (Select the 1 channel and 2 channel indications by the internal selection)
Specification
[Input] Number of channels 2 channels Thermocouple input K, J, E, T, R, S RTD input Pt 100 Ω (IEC751)
DC rated voltage 0 - 10 V, -10 -20 ㎷, 0 - 100 ㎷
1 - 5 V DC (with 4-20 ㎃ DC, attach 250 Ω external resistance)Contact input(DI) 8 contacts Input sampling time Each channel 500 ms Input impedance Thermocouple/dc voltage (㎷) : 1 ㏁, DC voltage(V) : Approx. 1 ㏁
DC current (4 - 20 ㎃ DC) : attach external resistance 250 ΩAllowable wiring resistance RTD : max 50 Ω/1 line(same resistance for 3 lines) Sensor current RTD : 300 ㎂ Detect input disconnection With the input break, it displays "---", Output OFF. Allowable input voltage DC low voltage (㎷DC) : 5 V DC / DC high voltage (V DC) : 15 V DC Input compensation ± 100.0 ℃ (Compensation is available for each interval) Input display resolution 1 digit of decimal point Memory function Setting and operation information (internal Flash and NVRAM) R.J.C accuracy Max ± 1.0 ℃ Scaling range -999.9 ~ 9999.9 Insulation resistance Min 20 ㏁. 500 V DC.(input terminal - earth terminal) Dielectric strength 2,500 V AC. 50 / 60 ㎐ for 1 min (infut terminal - earth terminal)fkls
[Performance] Display accuracy ±0.1 % of FS ±1 Digit (K, J, E, T)
±0.15 % of FS ±1 Digit (R, S)
±0.1 % of FS ±1 Digit (RTD)
±0.1 % of FS ±1 Digit (DC voltage)Insulation resistance Min 20 ㏁, 500 V DC (input terminal - earth terminal)
Dielectric strength 2500 V AC, 50 / 60 ㎐, for 1 min (input terminal - earth terminal)
[Control function and output]
● operation settingOperation type program control / Fixed value control selection
Limitation of SV rate change When performing Fixed value control, set the rate of change per min regarding the set value. Limitation of output rate change Limits an amount of output to become changed no more than 10 % (5% per 0.5 sec)
per second.Fixation control operation
time settingwhen performing fixed value control, set the operation time
(Set time : 9999 hour 59 min)Electrical failure backup handling STOP : operation setting, COLD : control again from the beginning,
HOT : control from the stopped point.BEEP melody selection Select the Beep melody when operating with touch panel Touch input lock Limits touch panel operation.
(With the state of lock, only possible to operate menu button and next button)Current time / operation time
reservation settingSet the time of system and the operation time reservation.
● Program setting Pattern setting Set the set value and PID group of segment in each patterns, segment time, standby function and time signal.
Segment input/delete Input or delete the segment of each pattern Time signal setting For the time signal of each segment, select either "segment ON/OFF" or "time operation". Start/end setting Select among start mode(SSV/PV1/PV2), end(RST/HOLD) mode and end segment Pattern repetition and connection Set the number of repetition of operation pattern and connection pattern
Segment and number of parts repetitiion.Standby operation setting Set the standby temperature range of each pattern and standby time.
● System setting Sensor input setting Thermocouple type / DC voltage input selection and sensor types, input or usable range, input compensation and input filter time. Control output setting Set the control mode (heating control/cooling control),
output types (current output, SSR, relay), A.R.W,
output cycle, ON/OFF Control dead zone, output direction (forward/reverse),
current output range and etcRetransmission output setting Set the retransmission output type of each channel (PV, SV, MV), output range, sensor
break output (0 ㎃, 4 ㎃), current output compensation value of each channel and etcInner signal setting Set the each number of inner signal (OFF, 1channel, 2channel), types (TSV, NSV, PV1, PV2), operation range, range direction (inside range, outside range), delay time and etc Alarm setting Set the observing condition of alarm operation (ALWAYS, RUN, FIX RUN, PROG RUN),
alarm code of each channel, alarm set value, hysteresis and etc.P.I.D setting Set the auto tuning gain of each channel, 4 types of PID group and level within each channel, PID auto/manual, auto tuning button (A/T)display, PID integer of each zone,
dead band and etcProportion band 0.0 ~ 1000.0 ℃ ( ON/OFF control when setting with "0") Integral time 0 ~ 6000 sec Differential time 0 ~ 6000 sec OF/OFF control hysteresis 0.1 ~ 1000.0 ℃ Proportional time 1 ~ 1000 sec A.R.W
(Anti reset windup)50 ~ 200 % (proportional band) Amount of output -5.0 ~ 105.0 % PID Zone 4 group (Level PID) Digital input (DI)
settingSet the operation type, standby time, valid point of time, DI name and etc. Digital output (DO)
settingCategorize the each signal output by actyal relay or open collector and select output number as for assign output number, alarm output number, time signal 18 contacts output number, input disconnection of each channel, operation of each channel, standby of each channel, hold of each channel, increase interval of each channel, maintain interval of each channel, decrease interval of each channel, contact input Error (DI Error), program end of each channel, I.S 1 and I.S number and output of series(AND) connection, I.S 2 and I.S number and output number of series (AND) etc.
Communication
settingSet the RS232C or RS485/422 communication function depends on the suffix code Other setting Language selection (Korean/English, Korean/Chinese), condition of each channel
(control function,indicate function, not using channel, channel operation at the same time, channel operation individually) selection.
● Control output Control output Relay Heating and cooling synchronous control (contact output (DO)is applied) N.O : 250 V AC 5 A, 30 V DC 5 A
N.C : 250 V AC 2 A , 30 V DC 1 ASCR Heating and cooling synchronous control Output signal : 4 - 20 ㎃ DC. (load resistance max 600 Ω Output accuracy ±0.1 % of FS Temperature drift : ±200 ppm/℃ (output part) SSR heating and cooling synchronous control Voltage pulse output : 24 V DC (load resistance min 600 Ω) Resolving power : smaller one between 0.1 % and 10 ms
● Retransmission output Retransmission output Output lists Select the Present value (PV), Set value (SV) and output amount of heating
side (H.MV) / output amount of cooling side (C.MV) in each channelCurrent output 4 - 20 ㎃ DC (By the scale setting) Resolving power 16 bits Output range Setting bound of scaling range Accuracy ±0.1 % of FS When performing heating/cooling control and if control output type of cooling side is SCR or SSR then corresponding channel cannot use retransmission output.
● Digital output (DO) Output number of contact Total 16 contacts (relay : 1c X 4 contacts, 1 a X 4 contacts / open collector : 8 contacts) Open collector 24 V DC. 300 ㎃ max. (load resistance) Relay contact N.O side 250 V AC 5 A or 30 V DC 5 A
N.C side 250 V AC 2 A or 30 V DC 1 A
(load resistance)
● Digital output (DI) Input number of contact Total 8 contacts Operate the Channels synchronusly
(1channel / 2channel)DI-1(RUN/RST)
DI-2~DI-4(RST)
DI-5(STEP/RST)
DI-6(HOLD/RST)
DI-7(HOLD-ON/RST)
DI-8(HOLD-OFF)Operate the Channels individually
(2channel)DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)
DI-1(CH.1 RUN/CH.1 RST/ERR/RST)ERROR input active RUN/Always selection Input signal Non voltage contact input (ON : max 10 Ω, OFF : min 500 kΩ