A variety of advanced yet easy-to-use features are apparent immediately to operators using MAGPOWR’s compact, powerful Cygnus® Tension Controls. Operators can easily navigate through advanced tension control functions and codes using on-screen prompts displayed in full text, making the setup process faster. Web tension is maintained or adjusted using multifunction “smart keys,” similar to those used in ATMs, and a large backlit display for easy viewing. Converters and printers can dramatically reduce setup time and improve consistency with powerful features like automatic tuning and out of round roll compensation (previously only possible with a dancer control). Complex tension settings can be input quickly with full text prompts as opposed to more complicated input procedures of the past.

  • Web Break Detection
  • Out-of-Round Roll Compensation
  • Bus Communication Capability
  • Auto Tuning
  • Weightless Load Cell Calibration
  • Advanced Load Cell Diagnostics
  • Gain Scheduling
  • UL and CE Approved

Closed Loop Control; small, powerful and feature-rich

MAGPOWR CYGNUS SPECIFICATIONS

  • CertificationsCE
    UL 508C Listed
  • Input
  • Supply Voltage115/230 VAC +/- 10%, 50/60 Hz, switch selectable
  • Tension Input0 to 21 mVDC (1 or 2, 350 Ω full bridges), 0 to 500 mVDC 
    (1 or 2, 120 Ω bridge), 0 to 5 VDC, 1 mADC maximum
  • Diameter Input0 to 10 VDC analog or calculated using velocity/rpm
  • RPM or Web Speed0 to 10 VDC analog, or 
    0.01 to 50,000 pulses per second, 5 VDC or 24 VDC logic
  • Auxiliary Input0 to 10 VDC
  • E-Stop, Run/Stop, Tension Off, Format, Spliceswitch closure, 
    5 or 24 VDC logic, active high or low
  • Output
  • Torque0 to 10 VDC, 4 to 20 mADC (500 Ω max), -10 to +10 VDC
  • Inverse Diameter0 to 10 VDC, 1 mADC maximum
  • Tension Reference0 to 10 VDC, 1 mADC maximum
  • Load Cell Excitation5 or 10 VDC, +5 and -5 VDC (10 VDC)
  • Low Tension (Web Break) Tension StatusDC solid state relay, 100 mADC 
    with a 1.6 VDC drop, 30 VDC max, or
    5 mADC with a 0.6 VDC drop 30 VDC maximum
  • Weight
  • Cygnus-DIN4 lb
  • Cygnus-E11 lb
  • Temperature
  • E-Operating32 to 104˚ F
  • DIN Operating32 to 122˚ F
  • Storage-22 to 176˚ F
  • Enclosure
  • Cygnus-DINFront Panel IP65 (IEC529)
    Enclosure IP20 (IEC529)
  • Cygnus-EIP65 (IEC529)
  • Bus Communication Gateways
  • COMMKIT-DNDeviceNet
  • COMMKIT-ENEthernet/IP
  • COMMKIT-PBProfibus-DP

Closed Loop Control; small, powerful and feature-rich